Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter (with Auto ID)
A EP Catheter Related Image
(Not Necessarily related to the device)
Description:
Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter (with Auto ID)
Presented by Innovative Health LLC, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter (with Auto ID) is a preeminent tool in the field of medical technology designed to facilitate real-time, highly accurate mapping of the heart during electrophydiological studies and ablations.
This advanced catheter is fast gaining recognition for its exceptional reprocessing capabilities which not only support efficient and eco-friendly practices, but also contribute to significant cost reductions for healthcare facilities. It is underlined by innovative auto ID technology which greatly simplifies catheter tracking and patient documentation, enhancing procedure speed and precision.
Key Features:
The bi-directional capability of the catheter allows for easier navigation and positioning within cardiac structures, potentially reducing procedure time and improving patient outcomes.
The auto ID feature facilitates rapid, error-free connections between the catheter and the recording system, reducing the risk of connection issues and ensuring reliable transmission of diagnostic information.
The reprocessing capability supports sustainability by facilitating multiple uses from the same device, reducing medical waste, and lowering costs without compromising on performance or safety.
In a rapidly evolving healthcare sector that is increasingly recognizing the importance of streamlined operations, precise diagnostics, and sustainable practice, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter (with Auto ID) presents an innovative solution for optimal cardiac diagnosis and treatment.
Primary Use:
Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter
A leading tool in the field of electrophysiology, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter serves an essential purpose in the diagnostic arsenal of a cardiologist.
One of its key functions revolves around enabling electrophysiological mapping of the heart. Often implemented in procedures such as cardiac ablations and EP studies, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter provides accurate, real-time intracardiac electrograms, which are vital to diagnosing numerous cardiovascular diseases.
Unique Bi-Directional Function
This catheter boasts a bi-directional feature, which facilitates precise maneuvering within the heart's intricate structure. This aids in creating accurate map representations of the heart, improving the precision and safety of diagnosing and treating cardiac conditions.
Additional Advancement - Auto ID Feature
An additional revolutionary technology integrated into the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter is the Auto ID feature. This advanced attribute ensures automatic identification, dramatically minimizing potential errors during a procedure and enhancing patient safety.
Through sophisticated design and technology, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter stays at the forefront of cardiac diagnostics and therapy, offering an efficient and trusted means towards superior patient care in the realm of cardiology.
How It Works:
Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter
Overview
The Reprocessed Webster CS bi-directional diagnostic EP Catheter is a leading product in the heart implant category that allows for intricate diagnostic and therapeutic procedures of the heart’s electrical system. Heart ImplantsFunctionality
The primary function of this catheter is to transmit electrical impulses and record cardiac electrophysiological responses from within the heart chambers. The Bi-directional capability enhances maneuverability by providing directional control and stability, which are pivotal in addressing complex cardiac arrhythmias. Cardiac ArrhythmiasDesign
The catheter boasts of an operative bi-directional deflection control handle designed for precision. A trademark of this product is its capacity to reprocess. Reprocessing is essentially the cleaning, sterilizing, and testing of the original device to ensure it is functioning as intended for reuse. This facet permits hospitals to optimize their resources effectively.
Auto ID feature
One salient feature of the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter is the Auto ID feature.
This permits a seamless integration of the catheter with an electro-anatomic mapping system, enhancing three-dimensional mapping and navigation capabilities. Electro-anatomic mapping
In conclusion, the Reprocessed Webster CS Bi-Directional Diagnostic EP Catheter demonstrates an evolution in medical device technology, encapsulating efficiency, environmental responsibility, and cost-effective solutions for the medical fraternity.
Manufacturer:
Innovative Health LLC.
Status: In Stock
Are you the owner or manufacturer of this device? Need to update anything on this page or get in touch with us? Click here.