YELLOW LASER PHOTOCOAGULATOR YLC-500 by NIDEK CO. LTD.

The YELLOW LASER PHOTOCOAGULATOR YLC-500 is a state-of-the-art medical device expertly designed and manufactured by NIDEK CO. LTD. Engineered to provide optimal precision and control, the YLC-500 is primarily used in advanced optometric procedures such as photocoagulation therapy.

The YLC-500's primary utility lies in its ability to treat a variety of retinal conditions including diabetic retinopathy, macular degeneration, and retinal vein occlusion. It functions by delivering targeted laser energy to the retina, initiating a healing response.

This cutting-edge photocoagulator brings a host of valuable attributes to the table. Most notably, it utilizes a yellow laser, which compared to the traditional green laser, offers superior melanin absorption, ensuring less energy is needed to achieve effective treatment. This translates into enhanced patient comfort and better treatment outcomes.

Furthermore, the YLC-500 boasts a specially designed laser slit lamp that enhances treatment effectiveness by providing a clear and wide field of view. This feature ensures operators can provide accurate, efficient, and comprehensive treatment of the retina.

The combination of these attributes places the YLC-500 at the forefront of retinal treatment aids, making it an essential tool for any modern optometrist or ophthalmologist. Capable of providing precise, effective, and comfortable treatment, NIDEK CO. LTD's YELLOW LASER PHOTOCOAGULATOR is a testament to the ongoing advancements in medical technology.


Primary Use:

Primary Medical Use of the Yellow Laser Photocoagulator YLC-500

Yellow Laser Photocoagulator YLC-500 is a state-of-the-art diagnostic tool designed to assist medical professionals with efficient and accurate diagnoses of a range of eye conditions. Specifically, it plays a pivotal role in the field of ophthalmology and has been established as a reliable resource in diagnosing and treating retinal and macular diseases.

Photocoagulation Process

The YLC-500's primary function is to perform a process called photocoagulation. As the term implies, photocoagulation involves the use of light to coagulate tissue. The procedure essentially uses a laser to deliver a concentrated beam of light to a small specified area in the eye. This results in a heating effect which seals off leaking blood vessels in the retina, stops bleeding, and repairs damaged tissues.

Key Applications

Yellow Laser Photocoagulator YLC-500 is effectively used in treating and managing conditions such as diabetic retinopathy, age-related macular degeneration, retinal vein occlusions, and peripheral retinal degenerations. The device allows flexibility in laser spot size, duration, and power to cater to different clinical requirements and patient conditions.
Remember, the YLC-500 is a versatile tool that can greatly aid in your clinical practice. It empowers you to provide prompt and focused care to your patients, thus leading to improved patient outcomes and enhanced patient satisfaction, setting your practice apart in the healthcare industry.


How It Works:

The Yellow Laser Photocoagulator YLC-500: Mechanics of Operation

Introduction: The Yellow Laser Photocoagulator (YLC-500) is a superior instrument for selective retina therapy and photocoagulation. This provides a safer, more effective option for patients needing retinal treatments. How it Works:
Yellow lasers such as the YLC-500 are classed as photocoagulation devices. The photocoagulation process involves the use of laser technology to coagulate blood or tissue, typically for therapeutic purposes. Mechanics:
The YLC-500, specifically, operates at the 577nm yellow wavelength, matching the peak absorption spectrum for both oxyhemoglobin and melanin, thus ensuring effective treatments. This selective absorption offers precise tissue targeting sparing surrounding tissues from damage. This results in minimal patient pain during the treatment and reduced chances of iatrogenic complications. Operational Features:
The device comes equipped with a SmartPulse technology. This added control helps to produce uniform, short-pulse laser burns, which ultimately leads to less spread of heat and conveniently adjustable pulse durations. Moreover, the YLC-500 comes with a True Yellow system enabling highest representation of outputs. Optimal Safety:
With the combined efficiency and accuracy offered by the yellow wavelength and SmartPulse technology, the YLC-500 minimizes post-operative inflammation and chorioretinal atrophy effectively. Applications:
This advanced technology offers broad-ranging applications, including the treatment of diabetic retinopathy, retinal vein occlusion, central serious chorioretinopathy and macular edema, and for performing pan-retinal photocoagulation and focal/grid photocoagulation. Conclusion:
The Yellow Laser Photocoagulator YLC-500 with 577nm yellow wavelength and SmartPulse technology is a robust addition to your practice as it assures effective treatment while minimizing patient discomfort and post-operative complications. With powerful filtering selections and precision, it brings an ideal blend of flexibility, performance, and patient safety.