HealthCareEquipment.org


Status: In Stock

Zilver 635 Biliary Stent


A Biliary Stent Related Image

(Not Necessarily related to the device)

Description:

Zilver 635 Biliary Stent by Cook Ireland Ltd.

The Zilver 635 Biliary Stent is a highly reliable and efficient medical device designed and manufactured by Cook Ireland Ltd. Specifically developed for non-vascular interventional radiology, it is prominently used for the palliative treatment of malignant neoplasms in the biliary tree.

The Zilver 635 Biliary Stent showcases a unique design featuring flared ends and a full-length radiopaque marker for superior placement accuracy and stability. Comprised of flexible and resilient material, it seamlessly adapts to the complex anatomy of the biliary duct, minimizing the risk of migration and providing sustained patient comfort.

Moreover, the stent’s advanced build ensures that it retains its shape and patency over an extended period, thus enhancing its effectiveness and durability. It offers a life-improving solution to patients suffering from obstructive symptoms or those unable to undergo surgery.

Used globally by healthcare practitioners, the Zilver 635 Biliary Stent is often commended for its easy deployment process, precision, resistance and adaptability. This medical device epitomizes Cook Ireland Ltd.'s commitment to delivering top-tier medical solutions aimed at improving patient outcomes and enhancing the quality of health care.


Primary Use:

Zilver 635 Biliary Stent: Primary Medical Use

Zilver 635 Biliary Stent, contrary to its listing, is not a device used in orthopedics; it belongs to the category of gastroenterological devices.
The primary use of the Zilver 635 Biliary Stent is in the treatment of biliary duct obstructions. These obstructions may result from various causes such as malignant tumors (cholangiocarcinoma, pancreatic cancer) or benign conditions (strictures, gallstones).
This sophisticated medical device essentially helps in restoring the normal flow of bile from the liver to the intestine. Once inserted via an endoscopic or percutaneous transhepatic procedure, the Zilver 635 Biliary Stent alleviates symptoms associated with bile duct obstructions such as jaundice, right upper quadrant pain, and cholangitis.
Its design involves a self-expanding feature, enabling it to adjust to the patient’s anatomy and maintain the patency of the bile duct.
In conclusion, while the Zilver 635 Biliary Stent is not an orthopedic implant, its essential function as a tool for maintaining bile duct patency in the presence of obstructions is highly valuable, making it an indispensable component within the realm of gastroenterology.


How It Works:

Zilver 635 Biliary Stent

The Zilver 635 Biliary Stent is a medical device that falls under the category of Orthopedic Implants. Understanding Biliary Stenting A biliary stent is typically used for the treatment of obstructive jaundice caused by benign or malignant lesions. The primary goal of these devices is to re-establish the normal drainage of bile. Working Mechanism The Zilver 635 Biliary Stent operates through a self-expanding mechanism. This distinct feature allows it to apply constant, gentle pressure on the surrounding tissue, which maintains an appropriate amount of radial force in order to hold the bile duct open. Here's a high-level overview of the Zilver 635 Biliary Stent working mechanism: 1. Upon its introduction into the bile duct, the device is in a contracted condition. This allows for smooth and uncomplicated navigation through the biliary anatomy. 2. Once positioned correctly, the stent begins to self-expand, applying force radially. 3. As it expands, it adapts to the lumen's shape and size, while simultaneously resisting its natural tendency to contract. 4. The biliary stent remains in this "permanent expanded" state allowing for effective duct patency.

A glimpse into the design

The Zilver 635 Biliary Stent exhibits a robust design providing excellent flexibility and kink-resistance, which is crucial for maintaining fluid flow. It incorporates a relatively high radial force to keep the lumen patent, ensuring seamless functioning. In conclusion, this device proves to be a reliable remedy for re-establishing bile flow in patients suffering from biliary obstruction. Its intelligent design and dynamic working mechanism make it exceptionally useful in both straightforward and challenging clinical scenarios.

Manufacturer:

Cook Ireland Ltd.


Status: In Stock


Are you the owner or manufacturer of this device? Need to update anything on this page or get in touch with us? Click here.

×

Owner/Manufacturer Registration

Thank you for your submission!

We will get in touch with you shortly.