Description:

ATTAIN LDS 6216A LEFT HEART DELIVERY SYSTEM ATTAIN ACCESS 6218A LEFT HEART DELIVERY SYSTEM ATTAIN 6216A AND 6218A GUID, MEDTRONIC INC.

Created by an industry leader in medical technology, the ATTAIN LDS 6216A Left Heart Delivery System, along with the ATTAIN ACCESS 6218A and ATTAIN 6216A and 6218A GUIDE set, designed by Medtronic Inc., represents a paramount innovation in cardiovascular interventions. These systems demonstrate an optimized instrument for device delivery and placement in left heart procedures, providing reliable and precise positioning of implantable cardiac devices.

The primary function of these systems is to deliver pacing leads, defibrillator leads, or other devices to specific locations within the left side of the heart. This is crucial in treating conditions like heart failure or arrhythmias, where the precise placement of therapeutic devices can substantially improve the patient's cardiac function and overall quality of life. They serve as beneficial tools in both surgical and minimally invasive procedures to provide optimal patient care outcomes.

The mechanism of action of these delivery systems involves introducing a guidewire and the delivery sheath into the vasculature using Seldinger technique. The guidewire is expertly maneuvered to the target location, using fluoroscopic guidance. It aids the advancement of the sheath and the implantable device along the tortuous path of the vascular system towards the precise target location in the heart. The systems are ergonomically designed to allow physicians intuitive operation while maintaining the highest degree of precision and control.

Apart from their exceptional function, these devices provide numerous significant benefits. Their innovative design ensures a smoother, less traumatic passage through the vasculature, minimizing potential damage to blood vessels. This further aids in enhancing patient safety and comfort. The cutting-edge technology incorporated in these devices ensures that they deliver high efficiency and precision, making them critical tools in enhancing the success of cardiovascular interventions.

Overall, the ATTAIN LDS 6216A Left Heart Delivery System, the ATTAIN ACCESS 6218A Left Heart Delivery System, and the ATTAIN 6216A AND 6218A GUID set from Medtronic Inc. represent remarkable advancements in medical device technology. They offer unparalleled effectiveness in ensuring precise device delivery and placement in left heart procedures--a vital necessity in current cardiovascular healthcare. With


Primary Use:

The 'ATTAIN LDS 6216A Left Heart Delivery System', 'Attain Access 6218A Left Heart Delivery System', and 'Attain 6216A and 6218A Guid' are cardiovascular surgical devices primarily used to facilitate cardiovascular interventions, specifically targeting the left side of the heart. The chief medical use of these devices is to deliver specialised therapeutic devices or therapies to precise locations within the heart, enabling medical practitioners to treat specific cardiovascular conditions. The 6216A and


How It Works:

The Attain LDS 6216A Left Heart Delivery System and the Attain Access 6218A Left Heart Delivery System are specialized cardiovascular surgical devices designed to aid in intravascular maneuvering and positioning of specific types of heart catheters and electrodes within the heart's venous system. These systems typically operate on advanced guiding mechanisms, crucial for minimally invasive cardiovascular procedures. Beginning with their utilization, the physician first introduces a guidewire into the patient's vasculature. Entry points generally include the femoral or subclavian veins. The wire is then advanced, under imaging guidance, to access the target area within the heart such as the atria or ventricles. Once the guidewire is in the precise location, delineated by the imaging, the sheath and dilator of the Attain system (in this case, the 6216A or 6218A model) are then introduced over the guidewire. The sheath serves as a smooth conduit to minimize tissue damage while providing a channel for direct delivery of the catheter or electrode. The dilator helps to expand the initial pathway to ease the introduction of subsequent implements. Following conduit setup, the guidewire and dilator are removed, leaving the sheath in place. Afterwards, the intended device, such as a pacing lead or an electrode, is threaded through the sheath to the target heart chamber. The lead or electrode can then be maneuvered with high precision using the delivery system. For pacing leads or electrodes, they are typically connected to a pacemaker or defibrillator device. Once positioned correctly, they can deliver electrical impulses that help pace the heartbeats, or provide shocks to correct any irregular heart rhythms. In general, the functionality of the Attain LDS 6216A and 6218A systems affords easier and safer access to the cardiac anatomy, derived from their flexibility and stability. These features help during the maneuvering of catheters and electrodes to their accurate positions within the patient's heart. Their use ultimately contributes to the improvement of therapeutic outcomes in cardiovascular patients while reducing possible risks associated to invasive cardiovascular procedures.

Manufacturer:

MEDTRONIC INC.