HealthCareEquipment.org


Status: In Stock

Medtronic Temporary External Pacemaker 53401


A Cardiac External Pacemaker Related Image

(Not Necessarily related to the device)

Description:

Medtronic Temporary External Pacemaker 53401 by MEDTRONIC INC.

The Medtronic Temporary External Pacemaker 53401 is a state-of-the-art device designed to provide cardiac pacing for patients whose natural heart rhythm is inadequate or completely absent. Primarily employed in coronary care units and operating theatres, it is designed for patients requiring short-term pacing support.

This external pacemaker measures and responds to the patient's inherent cardiac activity, adjusting its pacing output accordingly, making it practical for managing patients needing temporary cardiac pacing. It is especially beneficial in the postoperative management of patients who have experienced cardiac surgery or during an emergency when there is a need for rapid pacing support.

Key features of the Medtronic Temporary External Pacemaker 53401 provides patients with a high degree of safety and reliability. One of the defining characteristics of the device is its straightforward interface, which streamlines the provision of treatment and ensures ease of operation for health care professionals. A notable function is its sensitivity to react to intrinsic cardiac activity, covering a range from 0.5 mV to 20 mV. This feature ensures excellent patient-ventricular synchrony, minimising cardiac work while optimising haemodynamic status.

In conclusion, the Medtronic Temporary External Pacemaker 53401 is a versatile, reliable, and user-friendly device that offers high-quality temporary pacing support for patients–a critical life-saving tool in cardiac emergencies and post-surgical care.


Primary Use:

Medtronic Temporary External Pacemaker 53401: Primary Medical Use

Medtronic Temporary External Pacemaker 53401 falls under the wider category of cardiac pacemakers. As the name suggests, this advanced piece of medical equipment is intended for temporary pacing, and it plays a pivotal role in patient care within various cardiac scenarios.
Purpose
The Medtronic Temporary External Pacemaker 53401 is primarily designed to provide transcutaneous pacing, a life-saving intervention opulently used in emergency medicine. It offers temporary control over the heart's electrical pacing, which is crucial for patients suffering from severe bradycardia (abnormally slow heart rate), heart block, or any other conditions where the natural pacemaker of the heart fails, leading to hemodynamic instability.
Impact
This device is renowned for delivering direct and forestalling treatments, becoming a cornerstone in cardiac emergency management. Furthermore, it provides highly reliable pacing therapy in cardiac wards and during intraoperative and postoperative situations in cardiac surgeries, ultimately improving the survival and prognosis of patients.
Application
Medtronic Temporary External Pacemaker 53401 operates by delivering electrical impulses through the skin (transcutaneously) to depolarize the heart muscle and regulate heart rate. With its easy operation mechanism and precise pacing parameters, it allows for rapid therapeutic intervention, reducing the time between critical diagnosis and effective treatment. To sum up, the Medtronic Temporary External Pacemaker 53401 is an indispensable tool for healthcare professionals, providing them with a reliable, flexible, and efficient means to manage rhythm disorders and life-threatening cardiac conditions.


How It Works:

Understanding the Medtronic Temporary External Pacemaker 53401

The Medtronic Temporary External Pacemaker Model 53401, a prominent tool in cardiac rhythm management, is a robust device known for its durability and high-grade performance. It's a device of choice for numerous clinicians due to its potent functionality in handling cardiac pacing needs. Device Operation
The Medtronic Temporary External Pacemaker operates by delivering electrical impulses to the patient's heart. These electrical impulses are typically adjustable by the clinician to ensure that an ideal pace achieving symptomatic relief and physiologic synchronization is created. Key Features
Principle features of the device include: 1. It delivers single and dual-chamber pacing 2. It provides superior oversensing protection, preventing inappropriate under-pacing or competitive pacing 3. The device incorporates easily adjustable pacing parameters, fine-tuning it to each patient's vital requirements Functionality and Usage
Primarily, this pacemaker is designed for temporary cardiac pacing and is attached to a patient post-cardiac surgery or during an emergency, helping regulate the heartbeat until a long-term solution is achieved. It can be implemented in both single and dual chamber pacing, varying on patient needs. In single chamber pacing, the device can regulate ventricular functions directly. Alternatively, in dual-chamber pacing, the device can manage both atrial and ventricular pacing, henceforth offering comprehensive cardiac rhythm management.

Dealing with Potential Complications

Further precaution is taken in device design to minimize potential complications. The Medtronic Temporary External Pacemaker's oversensing protection feature ensures that potential risks associated with inappropriate under-pacing and competitive pacing are significantly reduced. To encapsulate, the Medtronic Temporary External Pacemaker 53401 perfectly combines advanced technology, clinician-friendly features, and robust performance, rendering it an ideal choice for temporary cardiac pacing needs.

Manufacturer:

MEDTRONIC INC.


Status: In Stock


Are you the owner or manufacturer of this device? Need to update anything on this page or get in touch with us? Click here.

×

Owner/Manufacturer Registration

Thank you for your submission!

We will get in touch with you shortly.