EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P by EDWARDS LIFESCIENCES LLC.

The EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P is a sophisticated heart valve replacement device skillfully developed and provided by the renowned EDWARDS LIFESCIENCES LLC. Designed to cater to the immediate or long-term requirements of heart valve replacement procedures, this medical device functions as an optimal choice to patients requiring aortic valve replacements.

The product's primary goal is to restore efficient and normal blood flow through the heart, thereby significantly improving the quality of life for the patient.

This bioprosthesis is stentless, which assures a more natural valve performance due to the facilitated geometry and dynamics that closely mimic those of a natural heart valve. Additionally, its enhanced hemodynamic function is designed to reduce stress on the left ventricle, favorably affecting the ventricular size, function, and potentially improving long-term patient outcomes.

Its advanced tissue preservation technology gives the EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P a distinct edge, facilitating long-term durability and performance that patients and healthcare providers can rely on. Such state-of-the-art technology accounts for the high quality and advanced performance that sets this bioprosthesis apart.

The EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P thus marks a remarkable stride in cardiac surgical interventions, providing countless patients with a renewed chance at a healthy life.


Primary Use:

EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500, 2500P - Primary Medical Application

The EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500, 2500P, classified under the 'Heart Implants' category, is designed to primarily serve as a replacement for damaged or malfunctioning aortic heart valves. The aortic valve is critical in maintaining the one-way flow of oxygenated blood from the heart to the major arteries of the body. A damaged aortic valve disrupts the natural blood flow, leading to various cardiovascular conditions. The EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500, 2500P occupies a crucial role in modern cardiac surgery, especially in treatments requiring aortic valve replacement. It replaces the damaged valve, restoring the consiten


How It Works:

Understanding the EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P

The EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P is a leading product in the heart implants category. It is an acellular, stentless pericardial aortic valve replacement designed using the latest in medical technology, with superior hemodynamic performance and a remarkable potential for durability.

Functionality and Operation

Acting as a surrogate for damaged or diseased heart valves, the device takes over the indispensable function of regulating blood flow from the heart. The primary advantage of a stentless valve, such as the Prima Plus, lies in its ability to ensure more natural flow dynamics, optimize left ventricle mass regression, as well as potentially enhance overall durability.
Due to the absence of a rigid stent framework, it offers lesser obstruction, leading to better hemodynamics and reduced stress on the leaflets. When compared to its stented counterparts, stentless valves are renowned for their superior hemodynamic performance, often demonstrating a superior effective orifice area (EOA), lower transvalvular gradients, and superior left ventricle mass regression.

Key Components

The Prima Plus by Edwards Lifesciences incorporates bovine pericardium treated with the proprietary ThermaFix process for durability and performance. The innovative design and technology effectively reduce calcification and increase the bioprosthesis's lifespan. Adoption of this technology indeed marks a significant step towards optimizing patient outcomes and enhancing clinical performance in aortic valve replacement surgeries.

Implantation

A stentless valve offers surgical versatility, hence it can be implanted as an intra-annular, supra-annular, or subcoronary. Albeit more technically challenging than stented valves, expertise in implantation can potentially optimize patient outcomes.
In conclusion, the EDWARDS PRIMA PLUS STENTLESS BIOPROSTHESIS MODEL 2500 2500P is an advanced, bio-engineered heart implant serving as an invaluable tool in managing aortic valve disease - offering excellent hemodynamic performance, potential longevity, and versatility in implantation.