Description:

HANCOCK MODIFIED ORIFICE (MO) VALVED CONDUIT MODEL 150 by MEDTRONIC HEART VALVES

The Hancock Modified Orifice (MO) Valved Conduit Model 150 by Medtronic Heart Valves is a state-of-the-art medical device specifically designed for cardiac surgery applications, specifically during heart valve replacements.
Engineered for superior hemodynamic performance and exceptional durability, the Hancock MO Valved Conduit is constructed from specially treated and high strength porcine tissue. This makes it remarkably resistant to calcification while safeguarding its elasticity and natural performance.
Perhaps one of the most noteworthy features of Model 150 is its 'modified orifice' design. This effectively maximizes the orifice area, leading to a reduction in transvalvular pressure gradients. Consequently, it promotes enhanced flow characteristics and improved patient outcomes.
Moreover, the Hancock MO Valved Conduit is also equipped with a flexible Dacron conduit, which facilitates ease of implantation, offering surgeons and clinicians unmatched control during surgical procedures.
Key benefits include:

In essence, the Hancock MO Valved Conduit Model 150 embodies high-quality materials, progressive design, and groundbreaking technology. This conduit not only improves surgical outcomes but also significantly enhances the quality of life for patients post-surgery.


Primary Use:

Introduction to the Hancock Modified Orifice (MO) Valved Conduit Model 150

The Hancock Modified Orifice (MO) Valved Conduit Model 150 is a highly specialized cardiac device. Its primary medical application is as an integral part of heart valve replacement surgeries. These surgeries are performed to deal with malfunctioning heart valves, which are crucial for maintaining unidirectional blood flow within the heart.

Functionality of the Hancock MO Valved Conduit Model 150

This device belongs to the family of bioprosthetic (biological) heart valves, primarily designed to replace diseased heart valves that have ceased to perform optimally. Specifically, the Hancock MO Valved Conduit Model 150 is typically utilized in aortic and pulmonary valve replacement proc


How It Works:

The Functionality of Hancock Modified Orifice (MO) Valved Conduit Model 150

Hancock Modified Orifice (MO) Valved Conduit Model 150, typically referred to as the Hancock MO Valve, is a renowned and highly effective device in the realm of cardiac medical intervention. The main purpose of this device is to replace or repair the malfunctioning of major heart vessels or valves, thus enhancing the blood flow capacity and overall heart function.

Device Components and Design

Constructed by Medtronic, the Hancock MO Valve is made up of two essential elements: a bioprosthetic valve and a conduit. The bioprosthetic valve, produced from porcine (pig) tissue, serves as a replacement for the patient's natural heart valve. The conduit, typically made from Dacron (a durable and blood-compatible material), serves as a kind of tunnel or bridge, allowing blood to flow through it effectively. This component is designed in a way that it securely houses and adapts the bioprosthetic valve.

Working Mechanism of the Hancock MO Valve

The Hancock MO Valve operates efficiently and its mechanism involves a simple functionality. Once the device is implanted into the patient's cardiovascular system, it acts in place of the damaged or diseased heart valve or vessel. The Bioprosthetic Valve: This valve operates by opening and closing according to the pressure changes within the heart. When the heart contracts, the valve opens to allow blood to flow out of the heart. Then, it closes to prevent the backflow of blood when the heart relaxes, thereby aiding in a one-way flow of blood, much like the natural heart valves. The Conduit: While the bioprosthetic valve engages in its opening and closing activity, the conduit ensures the smooth and unimpeded flow of blood by providing a passageway. The conduit is securely attached to the heart and the relevant vessel, offering an effective substitute for the natural vessel pathway. In sum, the Hancock Modified Orifice (MO) Valved Conduit Model 150 steps in resourcefully for the failing heart components by ensuring smooth blood recirculation, thereby working towards optimal patient health outcomes.