HealthCareEquipment.org


Status: In Stock

VICRYL Polyglactin 910 Sterile Synthetic Absorbable Surgical Suture PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Suture PDS Plus Antibacterial Polydioxanone Sterile Synthetic Absorbable Surgical Suture


Description:

VICRYL Polyglactin 910 Sterile Synthetic Absorbable Surgical Suture PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Suture PDS Plus Antibacterial Polydioxanone Sterile Synthetic Absorbable Surgical Suture by Ethicon Inc.

Ethicon Inc. produces the VICRYL Polyglactin 910, PDS II, and PDS Plus Abosrbable Surgical Suture products, widely used within the global medical community. These sutures are known for their high strength, durable and dependable nature in various surgical contexts.

The VICRYL Polyglactin 910 Sterile Synthetic Absorbable Surgical Suture is a product constructed from a copolymer made from 90% glycolide and 10% L-lactide. Noted for its tensile strength and smooth passage through tissues, the suture provides strong support during the critical healing period and then is absorbed by hydrolysis within six to eight weeks. This avoids the need for subsequent suture removal procedures and reduces patients' discomfort.

Our PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Suture is known for its extended wound support, up to six weeks. Its slow absorption profile provides peace of mind for both patients and surgeons for complex or long-term healing procedures. Such sutures are highly valued during surgeries that require sturdy tissue approximation or ligation such as abdominal and thoracic procedures, soft tissue repair, and pediatrics.

The PDS Plus Antibacterial Polydioxanone Sterile Synthetic Absorbable Surgical Suture benefits from the advanced addition of antibacterial agents. This innovative product provides all the superior properties of the PDS II line, but with an added layer of defense against potential bacterial colonization. This feature helps to minimize the risk of Surgical Site Infections (SSIs), a significant complication affecting post-surgical recovery. This results in better patient outcomes and shorter hospital stays.

In conclusion, all three sutures are designed with the core philosophy of providing safe, reliable, and advanced wound management options. Ethicon Inc. is dedicated to facilitating better patient outcomes with innovative, well-tested product lines.


Primary Use:

VICRYL Polyglactin 910 and PDS II Polydioxanone Synthetic Absorbable Sutures

Primary Medical Use:
The VICRYL Polyglactin 910 and PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Sutures are expertly-crafted medical devices typically used during surgeries for wound closure. They are absorbable, which means they are gradually and naturally broken down and absorbed by the body over time, negating the need for subsequent procedures to remove them. VICRYL Polyglactin 910:
This surgical suture is known for its high initial strength and durability, which aids in facilitating wound healing during the crucial initial period post-surgery. Wound support lasts for approximately two to three weeks, after which the suture will gradually lose tensile strength and get absorbed completely by the body within 56 to 70 days. PDS II Polydioxanone:
Unlike Polyglactin 910, the PDS II Polydioxanone suture has a longer absorption profile, taking up to six months for complete absorption. This makes it suitable for use in longer healing procedures, such as those involving the fascia, where prolonged wound support is required.

PDS Plus Antibacterial Polydioxanone Synthetic Absorbable Surgical Suture

Primary Medical Use:
The PDS Plus Antibacterial Suture, just like the PDS II, is an absorbable suture, but with an extra benefit – it is coated with triclosan, a broad-spectrum antibacterial agent. This feature further reduces the risk of wound contamination and infection post surgery, contributing to a safer recovery process for the patient. The suture retains ample strength for healing period and is also completely absorbed by the body over six months.

Importance in 'Cutting Tools' Category

These sutures are vital components of the 'Cutting Tools' category, playing a crucial role in the closure process following a surgical incision. Ensuring a clean and secure wound closure can significantly enhance the healing process and patient recovery timeline. These sutures provide doctors with trusted, reliable and effective wound closure options.


How It Works:

Greetings to fellow colleagues around the world

This document aims to explain the operational aspects of a medical device of paramount significance - the VICRYL Polyglactin 910 Sterile Synthetic Absorbable Surgical Suture PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Suture PDS Plus Antibacterial Polydioxanone Sterile Synthetic Absorbable Surgical Suture, classified under the category 'Cutting Tools'.

Understanding the Device

The device in question is a
Synthetic absorbable surgical suture crafted from Polyglactin 910 and Polydioxanone. The unique polymers used in this suture provide a robust and effective option for wound closure, minimizing the risks of infection and facilitating tissue healing.

Device Functionality

The VICRYL Polyglactin 910 Sterile Synthetic Absorbable Surgical Suture PDS II Polydioxanone Sterile Synthetic Absorbable Surgical Suture PDS Plus Antibacterial Polydioxanone Sterile Synthetic Absorbable Surgical Suture is utilized to approximate soft tissue and ligate during a surgical procedure. It is noteworthy that the suture is absorbable - it is slowly metabolized by the body over time, eliminating the need for suture removal post-operation.

Special Features

The device is infused with an antibiotic coating, providing it an antibacterial property. This assists in preventing common bacterial colonization on the suture and significantly reduces the risk of Surgical Site Infections (SSI).

Effectiveness

The selection choice of synthetic absorbable materials (Polyglactin 910 and Polydioxanone) ensures that the suture maintains its tensile strength for an extended period post-surgery - typically between 4 to 6 weeks. This timeframe aligns with the critical period of wound healing, thereby promoting optimal outcomes. In conclusion, the device provides a robust, safe, absorbable, and antibacterial option for wound closure in surgical practice. Incorporating this technology into your practice could provide significant advancement in patient outcomes.

Manufacturer:

Ethicon Inc.


Status: In Stock


Are you the owner or manufacturer of this device? Need to update anything on this page or get in touch with us? Click here.

×

Owner/Manufacturer Registration

Thank you for your submission!

We will get in touch with you shortly.